Weston cell



The Weston cell, invented by wet-chemical cell that produces a highly stable voltage suitable as a laboratory standard for calibration of voltmeters. It was adopted as the International Standard for EMF in 1911.

Contents

Chemistry

The solution of cadmium sulphate and the depolarizer is a paste of mercurous sulphate.

As shown in the illustration, the cell is set up in an H-shaped glass vessel with the cadmium amalgam in one leg and the pure mercury in the other. Electrical connections to the cadmium amalgam and the mercury are made by platinum wires fused through the lower ends of the legs.

Characteristics

The original design was a saturated cadmium cell producing a convenient 1.0183 Clark cell. (Reference cells must be applied in such a way that no current is drawn from them.)

The temperature coefficient can be reduced by shifting to an unsaturated design, the predominant type today. However, an unsaturated cell's output decreases by some 80 microvolts per year, which is compensated by periodical calibration against a saturated cell.

Patent

  • U.S. Patent 494,827 , "Voltaic cell"

See also

Sources

  • Practical Electricity by W. E. Ayrton and T. Mather, published by Cassell and Company, London, 1911, pp 198-203
 
This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article "Weston_cell". A list of authors is available in Wikipedia.